【24h】

Precision of the calibration of the AXAF engineering test article mirrors

机译:AXAF工程测试制品镜校准精度

获取原文
获取外文期刊封面目录资料

摘要

Measurements of the VETA encircled energies have been performed at 5 energies within 16 radii ranging from 0.05 to 200 arcseconds. We report here on the analysis of the accuracy of these measurements. A common 'error tree' structure applies, and we present representative numbers for the larger terms. At 0.277, 1.5, and 2.07 keV, and for radii of 3 arcsec and larger, our measurements have estimated 1 sigma errors of 0.6 to 1.5 percent. Effects of measurement statistics and of the VETA test mount limit the accuracy at smaller angles, and modulation by the counter window support structure together with the imperfect position repeatability limit the accuracy for the 0.93 and 2.3 keV energies. We expect to mitigate these limitations when calibrating the complex AXAF flight mirror assembly.
机译:veta环绕能量的测量已经在16个半径范围内的5个能量进行,范围为0.05至200个弧形。我们在此报告了对这些测量的准确性的分析。常见的“错误树”结构适用,我们为较大的术语提供代表性数字。在0.277,1.5和2.07 keV,并且对于3个Arcsec的半径和更大,我们的测量估计估计1的误差为0.6%至1.5%。测量统计数据的影响和veta测试安装座的效果限制了更小的角度的精度,并通过计数器窗口支撑结构的调制以及不完美的位置重复性限制了0.93和2.3 keV能量的精度。我们希望在校准复杂的Axaf飞行镜组件时减轻这些限制。