首页> 外文OA文献 >Precision of the calibration of the AXAF engineering test article (VETA) mirrors
【2h】

Precision of the calibration of the AXAF engineering test article (VETA) mirrors

机译:AXAF工程测试制品(VETA)反射镜的校准精度

摘要

Measurements of the VETA encircled energies have been performed at 5 energies within 16 radii ranging from 0.05 to 200 arcseconds. We report here on the analysis of the accuracy of those measurements. A common 'error tree' structure applies, and we present representative numbers for the larger terms. At 0.277, 1.5, and 2.07 keV, and for radii of 3 arcsec and larger, our measurements have estimated 1 sigma errors of 0.6 to 1.5 percent. Effects of measurement statistics and of the VETA test mount limit the accuracy at smaller angles, and modulation by the counter window support structure together with the imperfect position repeatability limit the accuracy for the 0.93 and 2.3 keV energies. We expect to mitigate these limitations when calibrating the complete AXAF flight mirror assembly.
机译:VETA环绕能量的测量已在0.05到200弧秒的16半径内的5种能量下进行。我们在此报告对这些测量准确性的分析。常见的“错误树”结构适用,我们为较大的术语提供了代表数字。在0.277、1.5和2.07 keV的情况下,对于3 arcsec和更大的半径,我们的测量结果估计1 sigma误差为0.6%至1.5%。测量统计数据和VETA测试支架的影响限制了较小角度的精度,而副窗口支撑结构的调制以及不完美的位置重复性限制了0.93和2.3 keV能量的精度。我们希望在校准整个AXAF飞行镜组件时减轻这些限制。