The authors present a PC-based real-time heart simulator to help design, test, and demonstrate the operation of advanced implantable device features. A PC half-card hardware assembly measures the pacing stimuli and defibrillation pulses from an attached implantable device. It also generates atrial (A) and ventricular (V) intracardiac waveforms to the device which are altered in real-time as either suprathreshold captured or subthreshold noncaptured pacing is detected. The software simulates the electrical interactions between the atria, AV node, and ventricles. Reentrant excitation is modeled via a ring of additional excitable nodes. The PC screen displays the surface or endocardial electrocardiograms and measured parameters such as A-A and V-V event intervals. The operator can initiate synchronous or asynchronous premature events and can interactively alter menu items such as cardiac rhythm, intrinsic rate, retrograde conduction time, pacing and defibrillation thresholds, respiration rate, and tidal volume.
机译:作者提出了一个基于PC的实时心脏模拟器来帮助设计,测试和演示先进的植入设备部件的操作。甲PC半卡硬件组件测量从附接的可植入装置的起搏刺激和去纤颤脉冲。它也产生心房(A)和心室(V)心内的波形,其在实时改变所捕获任一超阈值或亚阈值检测noncaptured起搏设备。该软件模拟心房,房室结,和心室之间的电相互作用。折返激发经由额外的可激发的节点的环建模。在PC屏幕显示表面上或心内膜心电图和测量的参数如A-A和V-V间隔的事件。操作者可以发起同步或异步事件过早和可以交互的alter菜单项如心律,固有速率,逆行导通时间,起搏和除颤阈值,呼吸率,和潮气量。