首页> 外文会议>Quantitative InfraRed Thermography Conference >Taking into account heat losses in front-face pulse IR thermography experiment for thermal diffusivity identification
【24h】

Taking into account heat losses in front-face pulse IR thermography experiment for thermal diffusivity identification

机译:考虑到前面脉冲IR热成像实验的热损失进行热扩散鉴定

获取原文

摘要

Thermal diffusivity can be measured by analysing the pulse response of the rear-face or of the front-face using a single detector or an IR camera. For the front-face configuration a simple identification method is proposed in the case of significant heat losses. The method is based on original correlations established between the occurrence times and values of the first and second logarithmic derivatives obtained by the thermographic signal reconstruction (TSR) method. The intrinsic accuracy of the identified diffusivity is evaluated by numerical simulations and validated by the analysis of experimental thermograms. Guidelines are proposed to optimise the identification procedure.
机译:可以通过使用单个检测器或IR相机分析后面或前面的脉冲响应来测量热扩散率。对于前面配置,在显着的热损失的情况下提出了一种简单的识别方法。该方法基于由热刻信号重建(TSR)方法获得的第一和第二对数衍生物的发生时间和值之间建立的原始相关性。通过数值模拟评估所识别的扩散率的内在精度,并通过实验热法图的分析来验证。提出指南以优化识别程序。