Concrete filled double skin steel tube (CFDST) is a new type of composite constructional element. Much research has been conducted on its performance in ambient temperature, whereas less attention has paid to the behaviour at elevated temperatures. This paper reports the FE analysis of the temperature distribution in concrete filled double skin tubes exposed to standard fire temperature. The effect of different heat contact conductance models for steel-concrete interfaces in FE model on predicted temperatures was investigated. Finally, temperature distribution in CFDST was discussed through comparing the temperature distribution in some typical concrete filled steel tubes (CFST) and CFDST elements.
机译:混凝土填充双皮钢管(CFDST)是一种新型复合结构元件。在环境温度下的性能下进行了许多研究,而不太关注的关注已经支付了升高的温度下的行为。本文报告了暴露于标准火灾温度的混凝土填充双皮管中温度分布的FE分析。研究了对预测温度的Fe模型中钢混凝土界面不同热接触电导模型的影响。最后,通过将一些典型的混凝土填充钢管(CFST)和CFDST元素的温度分布进行比较,讨论了CFDST中的温度分布。