ANALYSIS OF BUCKLING AND BENDING FAILURE OF ALUMINIUM COLUMN SECTIONS USED IN EMERGENCY RESTORATION TOWERS

机译:应急修复塔铝柱截面屈曲和弯曲失效分析

获取原文

摘要

This paper presents an experimental analysis of buckling and bending failure modes of a 2.58 m long, 460×460 mm~2 6061-T6 Aluminum alloy column section used in emergency restoration towers. The main objective is to determine the bending and buckling load capacities of the column section through experiments, as these values are critical in an emergency tower (guyed mast) design. Within the context of this overarching goal, a secondary objective is to ascertain whether the presence of certain manufacturing non-conformance affects the loading capacity of the section significantly. Finally, finite-element analysis (FEA) simulations are conducted in order to compare the experimental data with numerical results. The results show that the ultimate bending and buckling load capacities of the column section are 383 kN and 3,868 kN respectively. Furthermore, the results indicate that the presence of manufacturing non-conformances such as air bubbles and delamination do not have a detrimental effect on the load capacity of the column. Of the two non-conformances studied, the specimen with bubbles had a 1% difference from the good specimen, and the delaminated specimen had a 10% deviation. Comparison of experimental data with FEA simulation results shows that the numerical solution tends to overestimate the stiffness of the column, and that the FEA approach may require further calibration.
机译:本文呈现出2.58米长,460×460mm〜2 6061-T6铝合金柱部分的屈曲和弯曲损坏模式的实验分析。主要目的是通过实验确定列部分的弯曲和屈曲负载容量,因为这些值在紧急塔(Guyed Mast)设计中是至关重要的。在这种总体目标的背景下,次要目的是确定某些制造不合格的存在是否显着影响了该部分的负载能力。最后,进行了有限元分析(FEA)模拟,以便将实验数据与数值结果进行比较。结果表明,柱部分的最终弯曲和屈曲负荷容量分别为383 kN和3,868kn。此外,结果表明,在气泡和分层的制造不符合的存在对柱的负载能力没有不利影响。在研究的两个不合格中,具有气泡的样品与良好的样品具有1%的差异,并且分层标本偏差10%。实验数据与FEA模拟结果的比较表明,数值溶液倾向于高估柱的刚度,并且FEA方法可能需要进一步校准。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号