首页> 外文会议>International Conference on Power Electronics and ECCE Asia >Voltage Control Method in Non-linear Dead-time Effect Region for Dual Active Bridge DC-DC Converter
【24h】

Voltage Control Method in Non-linear Dead-time Effect Region for Dual Active Bridge DC-DC Converter

机译:双极电桥DC-DC转换器非线性死区区域的电压控制方法

获取原文

摘要

This paper proposes a voltage control method for a Dual Active Bridge (DAB) converter with three-level operation in the dead-time effect region. The non-linear transmission power error is reduced by controlling the zero current phase to the dead-time or more because the nonlinear error of the transmission power occurs when the inductor current reaches zero during the dead-time. In addition, the voltage control is operated under the linear region which is decided from the output current and the zero-voltage period. The validation of the proposed method is confirmed by a 2.3-kW prototype. In the experiments, the non-linear error in the transmission power is reduced by 76.3%. The linearity between a control variable and an output current is confirmed. In addition, a load step between two modes of three-level operation is achieved without the dc offset in the inductor current. Moreover, the RMS value of the inductor current is reduced by 50.2 % compared with the conventional triangular modulation.
机译:本文提出了一种用于双电桥(DAB)转换器的电压控制方法,在死区时间效应区域中具有三级操作。通过将零电流阶段控制到死区时间或更高,因为当电感电流在死区时间期间达到零时,通过将零电流阶段或更低控制来减小非线性传输功率误差。另外,电压控制在线性区域下操作,该线性区域从输出电流和零电压周期判定。所提出的方法的验证由2.3千瓦原型确认。在实验中,传输功率中的非线性误差减少了76.3%。确认控制变量和输出电流之间的线性度。另外,在电感器电流中没有DC偏移的情况下实现了两种模式之间的负载步骤。此外,与传统三角形调制相比,电感电流的RMS值减小了50.2%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号