首页> 外文会议>International Conference on Advanced Engineering and Technology >Experimental Measurement of the CO_2 Content in a Passive Home During a Simulated Air-Conditioning Power Outage
【24h】

Experimental Measurement of the CO_2 Content in a Passive Home During a Simulated Air-Conditioning Power Outage

机译:模拟空调停电期间无源家居CO_2含量的实验测量

获取原文

摘要

High concentrations of CO_2 are one of the causes of imperfect oxygenation of the blood circulation in humans. An experimental measurement of a passive home during a simulated power outage was carried out from July 7-15th 2014. In the measured rooms (one with plants with leaves the size of one of the bigger participants in this project, the second room without any plants at all), the levels of CO_2 were observed, as well as the levels of relative air humidity of the interior, and the interior temperature. The measurement was carried out at night, when sleeping time was simulated, i.e. the resting period. The impact of plants did not significantly influence the CO_2 reduction in the interior of the building. Regular airing is necessary for maintaining the hygienic limit of the concentration of CO_2. It is thus necessary to ensure this with the windows open during an unexpected power outage.
机译:高浓度的CO_2是人类血液循环缺乏的原因之一。在模拟停电期间的实验测量是从2014年7月7日开始的。在测量的房间(一个带有植物的植物,留下这个项目中的一个更大参与者的大小,第二间没有任何植物根本,观察到CO_2的水平,以及内部的相对空气湿度和内部温度的水平。在夜间进行测量,当模拟休眠时间时,即静止时间。植物的影响不会显着影响建筑物内部的CO_2。维持CO_2浓度的卫生极限是必需的常规播出。因此,必须在意外的停电期间使用窗户确保此功能。