首页> 外文会议>International Joint Conference on Biomedical Engineering Systems and Technologies >Image Quality Comparison between Digital and Synthetic 2D Mammograms: A Qualitative and Quantitative Phantom Study
【24h】

Image Quality Comparison between Digital and Synthetic 2D Mammograms: A Qualitative and Quantitative Phantom Study

机译:数字与合成2D乳房图之间的图像质量比较:定性和定量幻影研究

获取原文

摘要

The recent introduction of digital breast tomosynthesis (DBT) have lead to improvements in sensitivity and specificity of breast cancer detection, especially in cases of tumors developed in dense breasts. Since DBT provides tomographic slices of an entire tissue volume, it reduces the inherent tissue overlapping limitation of digital mammography (DM). In addition, DBT combined with DM has been proven to decrease recall and increase invasive cancer detection rates in breast cancer screening. However, the employment of DBT+DM implies a not negligible increment of patients absorbed dose. Therefore, Synthesized mammograms (SMs) generated from the DBT data have been recently introduced to eliminate the need of an additional DM. However, several studies showed differences between DM and SM images and some studies found contrasting results in terms of image quality when DM and SM images were compared. In our phantom study, we objectively compare image quality of SM and DM images in terms of noise, spatial resolution and contrast properties. Additionally, a qualitative analysis of the ACR mammographic phantom was performed in both modalities to assess the detectability of different features. SM images were characterized by different texture with respect to DM images, showing lower overall performances in terms of contrast-to-noise ratio and modulation transfer function. However, the goal of SM images is to provide a useful two-dimensional guide complementary to the DBT dataset and the performances in terms of high-contrast features detectability were satisfactory in comparison to those obtained in DM.
机译:最近引入数字乳房Tomos合成(DBT)导致乳腺癌检测的敏感性和特异性的提高,特别是在致密乳房肿瘤的情况下。由于DBT提供了整个组织体积的断层切割片,因此降低了数字乳房X线摄影(DM)的固有组织重叠限制。此外,DBT与DM相结合,已被证明可以减少召回并增加乳腺癌筛选中的侵入性癌症检测率。然而,DBT + DM的就业意味着患者吸收剂量的患者不可忽略的增量。因此,最近已经引入了从DBT数据产生的合成乳房X线照片(SMS)以消除额外DM的需要。然而,若干研究显示DM和SM图像之间的差异,并且一些研究在比较DM和SM图像时发现了图像质量方面的对比结果。在我们的幻影研究中,我们客观地比较了在噪声,空间分辨率和对比度方面的图像质量和DM图像。另外,在两种方式中进行了对ACR乳腺X线切相体的定性分析,以评估不同特征的可检测性。 SM图像的特征在于DM图像的不同纹理,在对比度与噪声比和调制传递函数方面表现出较低的整体性能。然而,SM图像的目标是提供与DBT数据集的互补的有用的二维引导,并且与在DM中获得的那些相比,高对比度特征可检测性的性能令人满意。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号