首页> 外文会议>Thermal Measurement, Modeling and Management Symposium >Development of a passively cooled outdoor telecom power enclosure
【24h】

Development of a passively cooled outdoor telecom power enclosure

机译:开发一款被动冷却的户外电信电源外壳

获取原文

摘要

This paper documents the development of a passively cooled outdoor electronics enclosure consisting of six 1.2kW AC/DC rectifiers (7.2kW total output power). Commercially available fan cooled rectifiers were used as a starting point and modified to be passively cooled using heat pipes and naturally-cooled heat sinks without changing the layout of the original circuit board. Several designs were considered, tested and modified to develop a fully passive thermal solution. The prototype was tested at ambient air temperatures of 26°C, 36°C and 46°C and it delivered 98.8%, 85.7% and 80.7% of its nominal output power at each of these temperatures, respectively.
机译:本文记录了由六个1.2kW的AC / DC整流器(7.2kW总输出功率)组成的被动冷却的户外电子机箱。市售风扇冷却整流器用作起点,并使用热管和自然冷热水槽被动地被动冷却,而不改变原始电路板的布局。考虑了几种设计,测试和修改以开发完全被动热溶液。在环境空气温度下在26℃,36℃和46℃的环境空气温度下进行原型,分别在这些温度下提供98.8%,85.7%和80.7%的标称输出功率。