Non-stationary behavior of roof drainage systems

机译:屋顶排水系统的非静止行为

获取原文

摘要

This paper reports the non-stationary behavior of a roof drainage during experimental measurement in the climate simulator. Many buildings use a fully or partially flat roof where it is necessary to use the roof drainage. Thermal behavior of roof drainage is very important from the point of view of heat transfer and potential condensation. The placement of a roof drain slightly deteriorates thermal transmittance of the roof. This experiment evaluates roof drains in the specific climate simulator where thermal conditions were dynamically controlled in the specific temperature range. The measurement was performed for two types of roof drains. The first drainage is a simple single-shell and the second is double-shell drainage. The results show the effect on the thermal transmittance of the roof section and also the minimal effect of condensation on the non-insulation part of the drainage. Both roof drains showed minimal deterioration of thermal transmittance of the roof construction.
机译:本文报告了气候模拟器在实验测量期间屋顶排水的非静止行为。许多建筑使用完全或部分平坦的屋顶,需要使用屋顶排水。从传热和潜在的凝结的角度来看,屋顶排水的热行为非常重要。屋顶排放的放置略微劣化屋顶的热透射率。该实验评估了在特定气候模拟器中的屋顶排水管,其中热条件在特定温度范围内动态控制。对两种类型的屋顶排水管进行测量。第一个排水是一个简单的单壳,第二个排水是双壳排水。结果表明了对车顶部分的热透射率的影响以及冷凝对排水的非绝缘部分的缩小效果。两个屋顶排水箱都显示出屋顶结构的热透射率的最小劣化。