The corrosion currents of steel bar in concrete with three W/B and four chloride contents after surface-painting two migrating corrosion inhibitors (PCI-2015 and MCI-A) 14d to 150d in atmospheric condition were measured. The results showed that the corrosion current density (I_(corr)) of steel bar reduced to 0.1 μA.cm~(-2) from the initial highest 3.833 μA.cm~(-2) (W/B=0.65, NaCl-1%) after surface-painting PCI-2015 14 d, and the I_(corr) was still lower than 0.1 μA.cm~(-2) until 150d. The compressive strength and chloride migration coefficient of concrete specimens were tested. The possible reasons of the mechanisms of durability improvement for reinforced concrete by applying PCI-2015 inhibitor were PCI-2015 may be reacted with calcium hydroxide in cement concrete and lots of inhibitor particles may be adsorbed on the active sites first and then a stable protective layer may be formed. The I_(corr) of steel bars in a hydraulic aqueduct concrete structure after painting PCI-2015, MCI-A (the United States) and MCI-B (Europe) during 6 months was monitored by Gecor 8 tester. The results showed that the average values of I_(corr) of steel bars after painting the PCI-2015 150d fulfilled the specification requirements in "Design code for concrete structure strengthening (E.3) "(GB50367-2013).
机译:测定了在大气条件下涂上两种迁移腐蚀抑制剂(PCI-2015和MCI-A)14d至150d后,用三个w / b和四氯化物含量的混凝土中的钢筋腐蚀电流。结果表明,钢条的腐蚀电流密度(I_(erc))从初始最高3.833μA.cm〜( - 2)(w / b = 0.65,nacl-)减少到0.1μA.cm〜(-2)。 1%)在表面绘制PCI-2015 14d之后,并且I_(COR)仍低于0.1μA.cm〜(-2)直至150d。测试了混凝土样本的抗压强度和氯化物迁移系数。施用PCI-2015抑制剂的耐脂混凝土耐久性改善机制的可能原因是PCI-2015可以与水泥混凝土中的氢氧化钙反应,并且批量抑制剂颗粒可以首先吸附在活性位置,然后是稳定的保护层可以形成。通过Gecor 8测试仪监测了在6个月内涂上PCI-2015,MCI-A(美国)和MCI-B(欧洲)后液压渡槽混凝土结构的I_(COR)。结果表明,绘画PCI-2015 150D后钢筋的I_(COR)的平均值满足了“混凝土结构强化设计代码(E.3)”(GB50367-2013)的规范要求。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号