首页> 外文会议>European Workshop on Modern Developments and Applications in Microbeam Analysis >Electron probe microanalysis of the dopant concentrations in complex perovskite ferroelectrics
【24h】

Electron probe microanalysis of the dopant concentrations in complex perovskite ferroelectrics

机译:复合钙钛矿铁电解中掺杂剂浓度的电子探针微分析

获取原文

摘要

Quantitative EPMA-WDS microanalyses were applied for the compositional characterisation of complex perovskite ferroelectrics based on cerium-doped barium titanate, a solid solution between lead-magnesium-niobate/lead-titanate and niobium-doped barium-bismuth-titanate. The analyses were optimized for high analytical sensitivity, precision and an ultimate accuracy of ≈ ± 1 % relative. The inherent problem with the WDS peak overlap of the Ce-Lα1 and Ba-Lβ_(1,4) spectral lines was solved by introducing overlap-correction methods in order to obtain consistent quantitative results for the Ce-doped BaTiO3. The quantitative results made it possible to obtain accurate chemical formulae for these materials, to determine the solubility of the dopants as well as to define the mode of the dopant incorporation and the charge-compensation mechanisms.
机译:基于铈掺杂的钛酸钡,铅 - 铌酸盐/铅和铌掺杂的钡 - 铋 - 钛酸盐的固体溶液应用了定量EPMA-WDS微母细胞的组合物表征。该分析针对高分析敏感性,精度和相对于±1%的最终精度进行了优化。通过引入重叠校正方法来解决CE-Lα1和BA-Lβ_(1,4)光谱线的WDS峰值重叠的固有问题,以便获得CE掺杂BATIO3的一致定量结果。定量结果使得可以获得这些材料的精确化学式,以确定掺杂剂的溶解度以及定义掺杂剂掺入的模式和电荷补偿机制。