The paper summarizes the results of numerical analysis conducted with the aim to compare the distribution of stresses in masonry pillars constructed using different bricklaying techniques. The analysis was carried out in reaction to the discussion of members of Czech standardization committee TNK 37 - Masonry structures. Currently, most of masonry load-bearing structures in the Czech Republic are made from clay blocks without mortar in perpend joints. The analysis seeks the answer to the question whether it is possible, in case of the eccentrically loaded masonry pillars with unfilled perpend joints, to consider the value of design compressive strength calculated using the same approach as for pillars with filled perpend joints for the check of vertical load resistance. Supplementary comparison of the behavior of the pillars with filled and unfilled perpend joints loaded by lateral load in the plane of the pillar (corresponding to short shear walls) was also conducted. 2D FEM model created in ATENA Science software was exploited for the analysis. The results confirmed that the approaches contained in CSN EN 1996-1-1 [1] are basically applicable for pillars with unfilled perpend joints.
机译:本文总结了进行数值分析的结果,目的是比较使用不同砌砖技术构造的砌体柱子中应力分布。该分析是对捷克标准化委员会TNK 37 - 砌体结构成员的讨论进行了反应。目前,捷克共和国中的大部分砌体承重结构都是由粘土块制成,没有砂浆在持续的关节中。分析寻求问题的答案是否有可能,与未填充perpend关节偏心受压砌体支柱的情况下,考虑使用相同的方法,用充满perpend接头的检查支柱计算的设计抗压强度值垂直载荷电阻。还进行了柱子(对应于短剪切壁)的侧向载荷的填充和未填充的持续接头的柱子的行为的补充比较。在Atena Science软件中创建的2D FEM模型被利用了分析。结果证实,CSN EN996-1-1 [1]中所含的方法基本上适用于未填充的持续关节的柱。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号