This paper presents a universal active filter for harmonic and reactive power compensation with UPS (uninterruptible power supplies) features. The configurations does not use transformer in the series part. Transformerless modern UPS systems have been rapidly replacing the old technology due to their performance and size attributes. Reducing the numbers of passive elements and/or switches in active power filters and UPS topologies not only reduces the cost of the whole system but also provides some other advantages, such as great compactness, smaller weight, and higher reliability.
机译:本文介绍了具有UPS(不间断电源)功能的谐波和无功补偿的通用主动滤波器。配置在串联部分中不使用变压器。由于其性能和大小属性,无变压器现代UPS系统一直在迅速取代旧技术。减少有源电源滤波器和UPS拓扑中的无源元件的数量和/或开关不仅降低了整个系统的成本,还提供了一些其他优点,例如具有大的紧凑性,重量较小和更高的可靠性。