首页> 外文会议>International Integrated Engineering Summit >Behavior of Fire Exposed Concrete-Filled Double Skin Steel Tubular (CFDST) Columns under Concentric Axial Loads
【24h】

Behavior of Fire Exposed Concrete-Filled Double Skin Steel Tubular (CFDST) Columns under Concentric Axial Loads

机译:火灾暴露的混凝土齐全的双皮钢管(CFDST)柱在同心轴向载荷下的行为

获取原文

摘要

This paper presents the result of an experimental investigation of axial behavior of concrete-filled double skin steel tubular (CFDST) columns exposed to high temperature under the action of monotonically applied concentric axial loads. The columns were exposed to ASTM E-119 standard fire curve until 600°C and kept constant for two different exposure time (i.e., 60 and 90 minutes). Failure patterns and reduction in strength, ductility and stiffness of CFDST columns are reported. Factors influencing the strength, ductility and stiffness of CFDST columns during fire exposure, i.e., exposure time, temperature of concrete core and temperature of inner steel tube, are also discussed.
机译:本文介绍了在单调施加的同心轴向载荷的作用下暴露于高温下暴露于高温的混凝土双层钢管(CFDST)柱的轴向行为的实验研究结果。将柱暴露于ASTM E-119标准火焰曲线,直到600℃,并保持恒定的两个不同的暴露时间(即,60和90分钟)。报道了CFDST柱的失效模式和强度降低,延展性和刚度的刚度。还讨论了影响火灾曝光期间CFDST柱强度,延展性和刚度的因素,即曝光时间,内钢管的混凝土温度和内钢管的温度。