This technical note reports findings on a series of squash tests to investigate the effects of a significant fire loading history on the axial load strength of concrete-filled, double-skin tube (CFDST) stub columns. Axial loading tests were conducted on two stub columns that were previously subjected to the first 60 minutes of the standard ASTM E119 (ASTM, 2012) fire. Results were compared to the resistance of an identical virgin stub column. Comparisons indicated an average reduction of 28% in the axial load strength of stub columns when subjected to the mentioned fire loading history.
机译:本技术说明报告了一系列壁球试验的结果,以研究大量火荷载历史对混凝土填充双层管(CFDST)短柱的轴向载荷强度的影响。轴向载荷测试是在两根短柱上进行的,这两根短柱先前曾经受过标准ASTM E119(ASTM,2012年)燃烧的前60分钟。将结果与相同的原始短管柱的抗性进行比较。比较表明,经受上述火荷载历史记录后,短柱的轴向荷载强度平均降低了28%。