首页> 外文会议>International Congress on Advances in Nuclear Power Plants >Chemical Degassing on EDF units - Feed Back Experience and Method
【24h】

Chemical Degassing on EDF units - Feed Back Experience and Method

机译:EDF单位的化学脱气 - 反馈经验和方法

获取原文

摘要

The chemical degassing feasibility of all French units RCS during outages is usually performed on the four 1500 MWe French units since July 2004 and is planned for 2007 on the 34 units of 900 MWe and the 20 units of 1300 MWe units. It helps to an optimized shutdown planning management, especially in case of unplanned shutdowns, and helps to limit the thermal stress corrosion of RHR at temperature higher than 120 deg C by avoiding temperature step extension after bubble collapsing to remove hydrogen increase. Chemical degassing is performed at temperature equal or lower than 80 deg C, by hydrogen peroxide injection if 3 < H_(2dissolved) < 35 cm~(3)/kg. H_(2)O_(2) calculation can be stoechiometric or increased by 20 percent depending on the SG tubes material and the full power operation duration before the shutdown. Purification flow is adapted to each design type units characteristics to easily manage a hypothetical early oxygenation. Early oxygenation management consists in forecasting the dilution of the VCT (Volume Control Tank) gaseous phase by nitrogen to avoid dangerous H_(2)/O_(2) gaseous mixture and to obtain oxygenation criteria on VCT. Three kinds of dilution can be used: nitrogen burping with high levels amplitude, continuous nitrogen flushing or discontinuous flushing with a maximal constant VCT level but pressure variation.
机译:在中断期间所有法国单位RCS的化学脱气可行性通常于2004年7月以来的四个1500 MWE法国单位进行,并计划在900 MWE的34个单元上计划2007年,而20单位为1300 MWE单位。它有助于优化的关闭计划管理,特别是在没有计划的停机情况下,通过避免在气泡塌陷以除去氢气的温度步延伸时,通过避免温度步延伸,有助于将RHR的热应力腐蚀限制在高于120℃。如果3

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号