KAERI has performed a series of blowdown tests to evaluate the performance of the prototypic sparger which will be used in the APR1400. Among the tests, the CPT-3 test is one of the fundamental blowdown tests and the objective of CPT-3 test was to determine the effect of air mass inside the piping on the IRWST boundary during an operation of SDVS (Safety Depressurization and Vent System). The test is conducted from the initial system pressure of 15.2 MPa and steam temperature of 343.2 °C. In the paper, the transient thermal-hydraulic behavior in the discharge line observed in the CPT-3 test is evaluated using the RELAP5/MOD3.1 code. The result shows that RELAP5/MOD3.1 can predict the blowdown behavior of the test facility properly and the code can be used as an evaluation tool for the verification of SDVS design of the APR 1400.
机译:KAERI已经进行了一系列排污测试,以评估原型喷射器的性能,将在APR1400中使用。在该测试中,CPT-3测试是基本排污试验之一,CPT-3试验的目的是在SDVS操作期间确定在IRWST边界内管道内的空气质量的影响(安全减压和排气系统)。该测试从初始系统压​​力为15.2MPa和蒸汽温度为343.2°C。在本文中,使用RETAP5 / MOD3.1代码评估CPT-3测试中观察到的排出线中的瞬态热液压行为。结果表明,RETAP5 / MOD3.1可以正确预测测试设施的排污行为,代码可用作验证4月1400的SDVS设计的评估工具。