The function of battery bank stores energy to the DC load in general, and DC power system of the nuclear power plant is used to supply DC loads for safety-featured instrumentation and control such as inverter, class 1E power system control and indication, and station annunciation. Class 1E DC power system must provide a power for the design basis accident conditions, and adequate capacity must be available during loss of AC power and subsequent safe shutdown of the plant. Batteries of Class 1E DC power system of the nuclear power plant uses lead-acid batteries in present. This paper analyzes a duty cycle and capacity design of lead-acid battery bank for the class 1E DC power system of nuclear power plant. In addition, parallel application of new secondary batteries is studied for smaller total size and extended lifetime of the energy storage system in nuclear power plant.
机译:电池组的功能通常将能量存储到DC负载一般,核电站的直流电源系统用于为安全特色仪器和控制提供DC负载,如逆变器,1E电力系统控制和指示以及站通告。第1E类直流电源系统必须为设计基事事故条件提供电力,并且在损失交流电源和随后的工厂安全关闭时必须提供足够的容量。核电站1E级直流电力系统的电池使用目前的铅酸电池。本文分析了核电站1E型直流电力系统铅酸电池组的占空比和能力设计。此外,研究了新的二次电池的并行应用,用于核电站储能系统的较小总尺寸和延长寿命。