CP1000, improved from 2~(nd) generation nuclear power plant technology, is a new concept of 2~(nd) plus technology, some improvements of which are relatively mature. Based on the technology of 2~(nd) plus, two new design improvements are being implemented, substituting high pressure safety injection with middle pressure safety injection and adding a function of fast cooling when an accident happens. Using code RELAP5, this article calculated and analyzed SGTR accident in order to evaluate the impact of the two improvements.
机译:CP1000,改进了2〜(ND)核电站技术,是2〜(ND)加科技的新概念,一些改进相对成熟。基于2〜(ND)加的技术,正在实施两种新的设计改进,用高压安全注入中压安全注射,并在事故发生时添加快速冷却功能。使用代码RELAP5,本文计算并分析了SGTR事故,以评估两种改进的影响。