首页> 外文会议>SPIE Conference on Optical Coherence Tomography and Coherence Domain Optical Methods in Biomedicine >Design of a swept-source, anatomical OCT system for pediatric bronchoscopy
【24h】

Design of a swept-source, anatomical OCT system for pediatric bronchoscopy

机译:用于小儿支气管镜检查的扫描源,解剖OCT系统的设计

获取原文

摘要

We describe the design and performance of a long coherence length, swept-source anatomical OCT (aOCT) system for pediatric airway imaging. A fiber-optic catheter is designed to be accommodated by a small-bore bronchoscope, and is scanned distally in a helical scan pattern to provide aOCT during bronchoscopy. We discuss particular challenges associated with the need for large imaging range, low SNR roll-off, and small catheter diameter. We present 3-D visualizations of airway phantoms and discuss optimization of the airway surface geometry obtained by aOCT. Accurate reconstruction of airway geometry will enable predictive modeling of patients suffering from airway obstruction.
机译:我们描述了用于儿科气道成像的长相干长度,扫掠源解剖OCT(AOCT)系统的设计和性能。光纤导管设计成通过小孔支气管镜容纳,并且在螺旋扫描图案中向远侧扫描,以在支气管镜检查期间提供AOCT。我们讨论了与大型成像范围,低SNR滚降和小导管直径的需要相关的特殊挑战。我们介绍了气道幽灵的3D透视图,并探讨了AOCT获得的气道表面几何形状的优化。气道几何的准确重建将使患有气道阻塞的患者的预测建模。