The development of eddy current inspection of the graphite bricks that comprise AGR interstitial channels is currently being pursued by EdF Energy. The eddy current probes are designed for detection of subsurface cracks, but can also be used for detection of bore cracks and measurement of graphite electrical resistivity. Modelling studies have been conducted by AMECFW to reduce the technical risk of developing the Inspection Tool. Comparisons have been made between experimental data and simulated signals generated using both the NDE simulator CIVA and the finite element simulator OPERA-3D. This paper describes the modelling studies conducted and presents a comparison of the results. Agreement between simulated and test amplitudes for an axial slot was within a factor of two in absolute terms. There was a tendency for the ratio of simulated to test amplitude to increase with frequency. There was good agreement between the CIVA and OPERA amplitudes and phases.
机译:目前正在通过EDF能量追求包括农业间质渠道的石墨砖的涡流检测的开发。涡流探头设计用于检测地下裂缝,但也可用于检测孔裂缝和石墨电阻率的测量。 amecfw进行了建模研究,以降低开发检查工具的技术风险。使用NDE Simulator Civa和有限元模拟器Opera-3D产生的实验数据和模拟信号之间进行了比较。本文介绍了所进行的建模研究,并提出了结果的比较。轴向槽的模拟和测试幅度之间的一致性在绝对术语中的两个倍数内。模拟与频率增加的测试幅度的比率存在趋势。 Civa和歌剧幅度与阶段之间存在良好的一致性。