The United States Army conducted a survey of over 1200 fuel samples with the objective of evaluating the proposed limits for use by automatic light obscuration particle counters for the monitoring of aviation fuel cleanliness. The laboratory data collected supports the proposed ISO code limit, based on ISO 4406, of 19/17/14/13 limits for the 4 μm(c)/ 6um (c)/ 14μm (c)/ 30μm (c) size channels. The proposed limits were derived from 1.0 mg/L concentration levels for ISO 12103-1 AlUltrafine and ISO 12103-1 A2 Fine test dusts, and down to a 5 ppm free water contamination. Based on this work the Department of Defense Tri-Service Petroleum, Oil and Lubricants Technical Steering Committee has recommended these limits for inclusion into Table I of MIL-STD-3004.
机译:美国陆军对超过1200种燃料样本进行了调查,目的是评估自动遮挡粒子计数器的建议限制,以监测航空燃料清洁度。收集的实验室数据支持基于ISO 4406的拟议的ISO码限制,19/17/14/13限制为4μm(c)/ 6um(c)/14μm(c)/30μm(c)尺寸通道。所提出的限制衍生自ISO 12103-1戊二酮的1.0mg / L浓度水平,ISO 12103-1A2微量试验粉尘,下降至5ppm的游离水污染。基于这项工作,国防部三役石油,石油和润滑油技术指导委员会建议将这些限制纳入MIL-STD-3004的表I。