首页> 外文会议>IEEE Nuclear Science Symposium Conference Record >Validation of NEMA NU4-2008 Scatter Fraction estimation with ~(18)F and ~(68)Ga for the ARGUS small-animal PET scanner
【24h】

Validation of NEMA NU4-2008 Scatter Fraction estimation with ~(18)F and ~(68)Ga for the ARGUS small-animal PET scanner

机译:Nema Nu4-2008施加〜(18)F和〜(68)GA为Argus小动物PET扫描仪验证

获取原文

摘要

The scatter fraction (SF) in PET data represents the fraction of coincidence events in which at least one of the two emitted photons have been scattered before being detected. It is usually estimated as the ratio of scattered events to total number of coincidences, when the number of random counts is negligible (less than 1% of true rates). SF provides a measurement of the relative sensitivity of the scanner to scattered radiation. It depends on object size, density and location inside the field of view, as well as on detector size, type of detector crystal and energy window. The performance evaluation guideline for small-animal PET NEMA (National Electrical Manufacturers Association) NU4-2008 proposes the estimation of the SF for three test phantoms made in proportion to the most widely used small animals in the laboratory: mouse, rat and monkey. The method estimates the different coincidence types in sinogram profiles from an off-centered line source inserted in these phantoms. We benchmark the procedure proposed by NEMA to estimate SF with ~(18)F and also with ~(68)Ga, a radionuclide with lager positron range. Real data acquired with the ARGUS small-animal PET scanner (SEDECAL, Madrid, Spain) as well as simulations of the same scanner with peneloPET are used. The results show that, though SF should be practically the same with both ~(18)F and ~(68)Ga isotopes (and indeed our simulations indicate this) NEMA SF estimations with ~(68)Ga acquisitions are higher. This is due to the fact that ~(68)Ga positron range affects on the width of the line source profiles. Suggestions to modify the protocol to obtain similar SF estimations when using isotopes with larger positron range than ~(18)F are made.
机译:PET数据中的散射级分(SF)表示重合事件的一部分,其中在检测到之前已经散射了两个发射的光子中的至少一个。当随机计数的数量可忽略不计(不到真实率的1%)时,通常估计是散射事件与偶合总数的比率。 SF提供了扫描仪以散射辐射的相对灵敏度的测量。它取决于视野中的对象大小,密度和位置,以及探测器尺寸,探测器晶体和能量窗口的类型。小型动物宠物NEMA(国家电气制造商协会)NU4-2008的绩效评估指南提出了三项测试幻像的估计,以与实验室中最广泛使用的小动物成比例地制成的三个测试幻影:小鼠,大鼠和猴子。该方法估计来自插入这些幻像中的偏心线源的铭顶谱中的不同巧合类型。我们将NEMA提出的程序基准测试以估计SF,〜(18)F以及〜(68)GA,一种带有贮藏正电子范围的放射性核素。使用Argus小动物PET扫描仪(SEDECAL,MADRID,SPAIN)获取的真实数据以及使用PONELINET的相同扫描仪的模拟。结果表明,虽然SF应该与〜(18)F和〜(68)GA同位素(以及我们的模拟表明这)NEMA SF估计与〜(68)GA收购更高。这是由于〜(68)GA正电子范围会影响线源轮廓的宽度。在使用比〜(18)F的具有较大正电子范围的同位素时,修改协议以获得类似的SF估计的建议。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号