Humidity Cell Tests: Effect of Air Flow and Cycle Duration in the Quality of Leachates

机译:湿度细胞测试:空气流量和循环持续时间在渗滤液质量的影响

获取原文

摘要

A factorial experimental design was used for humidity cell tests conducted for 10 cycles ontailings containing 71% pyrite to determine if the rate of air flow (3 and 6 Lmin~(-1)) and cycleduration (14 and 21 days) affected leachate pH, electrical conductivity, and Eh. The tailingscomposite sample for the tests was taken from Tizapa, a massive sulfide mine located southwestof Mexico City, Central Mexico. The method ASTM D 5744-96 was taken as the basis for thedesign of the cells with two modifications: 1) air was circulated across the surface of the tailingsand 2) water was dropped directly emulating rain on a tailings darn. Examining drainage qualitydata by cycles indicated the four treatments did not significantly affect the pH, but it was foundthat the air flow rate had a significant effect in the quality of leachates. The higher air flowdelayed acidification, probably due to excessive water loss that inhibited oxidation reactions.
机译:阶乘实验设计用于含有71%硫铁矿的10个循环的湿度细胞试验,以确定空气流量(3和6 Lmin〜(-1))和循环率(14和21天)是否影响渗滤液pH值,电导率和eh。用于测试的尾矿复合样品是从墨西哥中部墨西哥城西南部的大规模硫化物矿的TAZAPA。该方法ASTM D 5744-96作为具有两种修改的细胞的基础:1)空气在尾矿和2)水面上循环,落在尾矿DARN上直接模拟雨水。通过循环检查排水质量表明,这四种治疗没有显着影响pH值,但它是基于空气流速对渗滤液质量产生显着影响的影响。较高的空气流量酸化,可能是由于抑制氧化反应的过度水分。