The research work presented in this paper shows that it is possible to obtain considerable energy savings by using more energy efficient heat exchangers in indirectly cooled display cabinets in supermarkets. Experimental investigations of traditional cooling coils and plain fin flat-tube heat exchangers have been sandwiched with theoretical parameter studies. The purpose of the experimental studies was to find which models, correlations and assumptions that best described the heat transfer and pressure drop performance of the heat exchangers and the mast appropriate ones were applied in the parameter studies. One objective was to find a heat exchangers design efficient enough to satisfy the cooling demand of the display cabinet with such a small temperature difference that frosting and defrosting could be avoided. This objective was reached and avoiding frosting and defrosting of the heat exchanger in the display cabinet would result in an improved temperature quality of the displayed provisions.
机译:本文提出的研究工作表明,通过在超市中的间接冷却的展示柜中使用更多节能热交换器,可以获得相当大的节能。传统冷却盘管和普通翅片平管热交换器的实验研究已夹在理论参数研究中。实验研究的目的是找到最能描述热交换器和肥大适当的模型,相关性和假设的模型,相关性和假设,以及适当的参数研究。一个目的是找到一种热交换器设计有效,以满足展示柜的冷却需求,具有这种小的温差,即可以避免磨砂和除霜。该目的是达到的,避免了显示柜中的热交换器的磨砂和除霜会导致显示的展示规定的温度改善。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号