Stabilizing the indoor air temperature and optimizing the distribution of heat are the important parameters to improve the performance of solar air heating building. This study analyzed the influence of the concrete slab's behavior as thermal mass to smoothing the fluctuation of temperature by experimental research on the real building with south wall-mounted solar air collector under different conditions. Then, based on the experimental results, the impacts of different thermal mass levels and the position of thermal mass in the building on indoor thermal environment were analyzed by using the software EnergyPlus. Main conclusions are drawn as follows: the total thermal capacity of building bigger, the smaller the temperature's fluctuation, yet, when the capacity were big enough this effect can be neglected; the best capacity ratio of external thermal mass to internal thermal mass is 5:1; the heat transfer coefficient of internal thermal mass is the bigger, the better.
机译:稳定室内空气温度并优化热量分布是提高太阳能空气加热建筑的性能的重要参数。该研究分析了混凝土板行为作为热质量的影响,以平滑温度的水平,在不同条件下用南壁安装太阳能集热器的实验研究对温度的实验研究。然后,根据实验结果,通过使用软件能量分析,分析了不同热质量水平和在室内热环境中建筑物中热质量位置的影响。主要结论如下:建筑物的总热容量较大,温度波动越小,然而,当容量足够大时,这种效果可以忽略;外部热质量与内部热质量的最佳容量比为5:1;内部热质量的传热系数是更大的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号