1. A rigorous NSB experiment is imperative for a true indication of NSB. Critical elements such as using pipettes for transferring from tube to tube and evaluating multiple urine lots should be incorporated into a NSB experiment. 2. The larger the surface area, the more NSB loss; therefore, keep sample volumes <20% of the total tube volume for the experiment. In addition, the experiment should be performed at a concentration near the LLOQ so that NSB loss can definitively be detected. 3. The length of time does not seem to be a key factor in NSB loss; therefore, a wait step in between each tube transfer is not important. The wait step will be removed from our current approach. 4. At least six transfers should be evaluated, as only two or four transfers may not show a significant loss due to NSB. 5. The number of transfers and the significance of the observed NSB loss is partially dependent on how many transfers the study sample will experience from collection through analysis.
机译:1.严谨的NSB实验必须迫切地表明NSB。诸如使用移液管以从管转移到管和评估多个尿素批次的关键元件应纳入NSB实验。 2.表面积越大,NSB损失越多;因此,保持样品体积<20%的实验中总管体积的20%。此外,实验应以靠近LLOQ的浓度进行,以便能够明确地检测NSB损耗。 3.时间长度似乎不是NSB损失的关键因素;因此,每个管道转移之间的等待步骤并不重要。等待步骤将从我们当前的方法中删除。 4.应评估至少六个转移,因为只有两个或四个转移可能不会出现由于NSB而产生的显着损失。 5.接送的数量和观察到的NSB损失的重要性部分取决于通过分析将研究样本从收集经历的数量有数量的转移。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号