Temperature load is one of the main loads for arch dams, especially in the area with large temperature fluctuation, in which case the impact of cold waves is often more critical than hydraulic load. Therefore, it is desirable to study the operating performance of arch dams under extreme temperature conditions in order that some valuable knowledge can be given to guide the design of arch dams. In this paper, the research is performed on Laxiwa arch dam to analyze the stress distributions of the dam body in the cases of annual operation condition and extreme cold wave period. Then, a permanent surface thermal insulation measure is simulated in the analysis to determine its effect on dam stresses. The results demonstrate that, a surface thermal insulation measure with additional local thickening on the downstream surface is efficient to reduce the maximum tensile stress of the dam body and it is necessary to be used to eliminate possibility of dam concrete cracking.
机译:温度负荷是拱坝的主要负载之一,尤其是温度波动大的区域,在这种情况下,冷波的冲击通常比液压负荷更为关键。因此,希望在极端温度条件下研究拱坝的操作性能,以便可以给出一些有价值的知识来指导拱坝的设计。本文在兰西瓦拱坝进行了研究,分析了在年度操作条件和极端冷波期的情况下坝体的应力分布。然后,在分析中模拟了永久性表面热绝缘度量,以确定其对坝应力的影响。结果表明,在下游表面上具有额外局部增厚的表面绝热度量是有效的,以降低坝体的最大拉伸应力,有必要用于消除坝混凝土裂缝的可能性。