首页> 外文会议>International Conference on Long Time Effects and Seepage Behavior of Dams >STUDY ON THE QUALITY CONTROL TECHNOLOGY FOR LAYER BOUNDARIES OF RCC OF NANSHA HYDROPOWER STATION
【24h】

STUDY ON THE QUALITY CONTROL TECHNOLOGY FOR LAYER BOUNDARIES OF RCC OF NANSHA HYDROPOWER STATION

机译:南沙水电站RCC层边界质量控制技术研究

获取原文

摘要

Nansha power station is located in a typical sub-tropical climatic region with high temperature and low humidity, where high-temperature time of the year is up to 70%. The RCC is very difficult to be placed in such climatic conditions. In this paper, the effects of environmental conditions and admixture on RCC set-time and the effects of different treatment processes on the quality of layer boundaries are studied. Field observation of dam shows that the quality of layer boundaries can be ensured by the comprehensive use of construction technical measures such as optimizing concrete mix ratio, damp preservation and cooling by spraying, sun protection, rapid construction and the control of interval time between placing of different layers.
机译:南沙发电站位于典型的亚热带气候区域,具有高温和低湿度,其中一年的高温时间高达70%。 RCC很难被置于这种气候条件下。本文研究了环境条件和外加剂对RCC设定时间的影响以及不同处理过程对层边界质量的影响。 DAM的现场观察表明,通过综合使用施工技术措施,可以通过喷涂,防晒,快速施工和在放置之间的间隔时间控制间隔时间来实现施工技术措施,如优化混凝土混合比,潮湿保存和冷却的局面边界的质量不同的层。

著录项