首页> 外文会议>Topical Conference on Radio Frequency Power in Pasmas >Lifetime Prolongation of ICRF Generators, Practical Aspects and Results
【24h】

Lifetime Prolongation of ICRF Generators, Practical Aspects and Results

机译:ICRF发电机的寿命延长,实践方面和结果

获取原文

摘要

To overcome final tube obsolescence of 2MW generators in service for AUG and to gain hands on experience with a potentially ITER relevant tetrode from CPI, a 1.5MW generator, previously used for ASDEX and W7-AS and described in [4], was converted using a 4CM2500KG based plug & play replacement for the CQK650-2 tetrode. A similar conversion, substituting a different tetrode was reported in [3] and served as a guideline. IPP Garching reactivated the generator that had been out of service for many years and prepared and tested the required infrastructure. A mechanical adaptation kit designed by ITER India was manufactured by IPP Garching. Fitting the generator with the tube replacement and testing it was a joint activity at IPP Garching. With a careful tune up the generator achieved 1.5 MW RF output power. Further infrastructural improvements to reach 2MW are on the way.
机译:为了克服8月份服务中的2MW发电机的最终管过时,并通过来自CPI的潜在迭代相关的Tetrode的潜在迭代的经验,以前用于ASDEX和W7的1.5MW发电机,如[4]中所述,以后转换基于4CM2500kg的CQK650-2 Tetrode的即插即用替换。在[3]中报道了代替不同的四极管的类似转化,并作为指导。 IPP Garching重新激活了多年来已经过时的发电机,并准备并测试了所需的基础设施。由ITER印度设计的机械适应套件是由IPP GARCHING制造的。用管子更换和测试将发电机安装在IPP GARCHING上是一种联合活动。通过仔细调整发电机实现1.5 MW RF输出功率。达到2MW的进一步基础设施改进正在进行中。