首页> 外文会议>Institute of Nuclear Materials Management annual meeting >IMPROVEMENTS IN THE ACCURACY OF THE U235 MEASUREMENT IN WASTE DRUMS AT BNFL'S DRIGG SITE
【24h】

IMPROVEMENTS IN THE ACCURACY OF THE U235 MEASUREMENT IN WASTE DRUMS AT BNFL'S DRIGG SITE

机译:BNFL的Drigg站点的废话中U235测量的准确性提高

获取原文

摘要

Accurate determination of the U235 content of Plutonium Contaminated Material (PCM) wastes generated during retrieval operations at BNFL's Drigg Site is complicated by the potential presence of self-shielding lumps of uranium. The routine assay functions of the Drigg Drum Monitors are unable to determine whether uranium lumps are present, and hence pessimistic assumptions regarding the degree of self-shielding in any uranium present have been applied in the calibration, to meet criticality safety requirements. A significant number of drums have been measured as having U235 content greater than the limits defined in the criticality clearance certificates, however it is likely that the U235 content of these drums has been grossly overestimated because of the assumed self-shielding (which equates to approximately a factor of eight compared to infinitely dilute uranium). These high U235 content drums present significant operational problems. To address this issue, BNFL Instruments have developed a technique for identifying whether lumps of uranium are present. If the uranium present can be proven to be dilute, then the U235 result is reduced by removal of the assumed level of self-shielding from the calibration. To support the introduction of this technique and to determine whether lumps of uranium are genuinely present in the waste, twelve of the highest U235 content drums were selected for physical repacking. These drums were opened and individual waste packets removed and physically inspected to look for evidence of lumpy material. The packets were then placed within new drums and re-assayed to determine their fissile content. Additional measurements were then performed of the highest U235 content packets from each original drum, to obtain high quality gamma spectra for the analysis. The analysis results indicated that two of the twelve drums contained significant lumps of uranium, with the remaining ten being dilute. The waste measurement results presented in this paper demonstrate the applicability of this technique, which will now be applied to future high U235 content waste drums to improve the accuracy of the U235 measurement and to avoid unnecessary drum repacking.
机译:准确测定BNFL的Drigg站点的检索操作期间产生的钚污染物质(PCM)废物的含量,因铀的潜在存在的潜在存在而变得复杂。 Drigg鼓监察器的常规测定功能无法确定是否存在铀块,因此对存在的任何铀的自屏蔽程度的悲观假设已应用于校准,以满足临界安全要求。已经测量了大量的鼓,其具有大于临界清除证书中定义的限制的U235内容,但是由于假定的自屏(其等于大约),这些鼓的U235内容可能严重高估了与无限稀释铀相比,八倍)。这些高U235内容鼓具有显着的操作问题。为了解决这个问题,BNFL仪器已经开发了一种识别存在铀肿块是否存在的技术。如果可以证明存在的铀,则通过从校准中移除假定的自屏蔽水平来降低U235结果。为了支持这种技术的引入并确定铀是否真正存在于废物中,选择了最高的U235内容鼓的物理重新包装。打开了这些鼓,并将单独的废物包移除并物理检查,以寻找块状物质的证据。然后将包裹置于新鼓内并重新测定以确定其裂变含量。然后对来自每个原始鼓的最高U235内容分组进行额外的测量,以获得高质量的伽马光谱进行分析。分析结果表明,十二鼓中的两种含有巨大的铀,其余十个稀释。本文提出的废测量结果表明了该技术的适用性,现在将应用于未来的高U235内容废滚筒,以提高U235测量的准确性,并避免不必要的滚筒重新包装。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号