Radiation Suppression Ratio Measurement of Noise Suppression Sheet by Compact 3m Method

机译:Compact 3M方法辐射抑制比测量噪声抑制片

获取原文

摘要

A noise suppression sheet (NSS) is used for decoupling of the noise path, suppressing RF noise current, and reducing radiation. A microstrip line (MSL) test fixture is also used for measuring the radiation suppression ratio (Rrs) [1] as the antenna. The ratio is derived from a comparison before and after the NSS installation in accordance with CLSPR22, the 3m or 10m test method in an anechoic chamber, or an open-area test site. A new method for determining the Rrs that can replace the 3m and 10m test methods is described here. This new compact 3m method involves the use of a NSS sample, dielectric lens, receiving antenna, and network analyzer. The features of this method are as follows: 1) there is no anechoic chamber, 2) it is compact, 3) it is easy to change the sample because of the vertical system design, and 4) it requires no power amplifier or low noise amplifier because the EM wave is not spread.
机译:噪声抑制片(NSS)用于噪声路径的去耦,抑制RF噪声电流和减少辐射。微带线(MSL)测试夹具还用于测量辐射抑制比(RRS)[1]作为天线。该比率是根据CLSPR22,3M或10M测试方法的NSS安装之前和之后的比较来源的,或者在一个开放式区域测试站点中。这里描述了一种用于确定可以代替3M和10M测试方法的RRS的新方法。这种新的紧凑型3M方法涉及使用NSS样品,介电镜头,接收天线和网络分析仪。该方法的特征如下:1)没有一个AneChoice腔室,2)紧凑,3)由于垂直系统设计,易于改变样品,4)它不需要功率放大器或低噪声放大器因为EM波没有传播。