首页> 外文会议>International Conference on Fracture >Determination of the mechanical properties of normal and calcified human mitral chordae tendineae
【24h】

Determination of the mechanical properties of normal and calcified human mitral chordae tendineae

机译:确定正常和钙的人体腹股沟腱腹力学的测定

获取原文

摘要

The aim of the present research is to determine the influence of the calcification of human mitral valves on the mechanical properties of their marginal chordae tendineae. The study was performed on marginal chords obtained from thirteen human mitral valves, explanted at surgery, including six non-calcified, four moderately calcified and three strongly calcified valves. The mechanical response of the chords from the non-calcified and moderately calcified valves was determined by means of quasi-static tensile tests (the poor condition of the strongly calcified valves prevented them from being mechanically characterised). The material parameters that were obtained and analysed (the Young's modulus, the secant modulus, the proportional limit stress, the ultimate strength, the strain at fracture and the density of energy stored up to maximum load) revealed noticeable differences in mechanical behaviour between the two groups of mitral chordae tendineae. Large scatter was obtained in all cases, nevertheless, considering the mean values, it was observed that the normal chords are between three and seven times stiffer or more resistant than the moderately calcified ones. On the contrary, the results obtained for the strain at fracture showed a rather different picture as, in this case, no significant differences were observed between the two families of chords. A scanning electron microscopy study was conducted in order to find out the relevant features of the calcium deposits present in the calcified chordae tendineae. In addition, the general aspects appreciated in the stress vs. strain curves were correlated with the collagen morphological evidences determined microscopically. Finally, the calcium content present in the three groups of chords was quantitatively determined through atomic absorption spectroscopy; then, the relation between the mechanical properties of normal and moderately calcified chords as a function of its calcium content was obtained. This analysis confirmed the existence of a strong correlation between calcium content and stiffness or resistance whereas the influence on the ductility seems to be negligible.
机译:本研究的目的是确定人二尖瓣钙化对其边缘Chordae肌腱的力学性能的影响。该研究进行了从三十人二尖瓣获得的边缘和弦,在手术中脱盐,包括六个非钙化,四个中度钙化和三个强钙化阀。通过准静态拉伸试验确定来自非钙化和中晶阀的和弦和中等钙化阀的机械响应(强钙化阀的差状况较差,防止它们机械表征)。获得和分析的材料参数(杨氏模量,分度模量,比例极限应力,骨折处的菌株以及存储在最大载荷的能量的密度)揭示了两者之间的机械行为的显着差异腹股沟群组群体。然而,在所有情况下都获得了大的散射,考虑到平均值,观察到正常和弦在比中等钙化的抗性或更抗性的三倍和更抗性之间。相反,在裂缝处菌株获得的结果显示出相当不同的图片,因为在这种情况下,在两个和弦之间没有观察到显着差异。进行扫描电子显微镜研究,以便找出钙化曲折​​培养植物中存在的钙沉积物的相关特征。另外,在应力与应变曲线中欣赏的一般方面与显微镜确定的胶原形态证据相关。最后,通过原子吸收光谱定量地测定三组弦中存在的钙含量;然后,获得了正常和中等钙化和弦作为其钙含量的函数的力学性能之间的关系。该分析证实存在钙含量和刚度或阻力之间的强相关性,而对延展性的影响似乎可以忽略不计。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号