首页> 外文期刊>Journal of the mechanical behavior of biomedical materials >Determination of the mechanical properties of normal and calcified human mitral chordae tendineae
【24h】

Determination of the mechanical properties of normal and calcified human mitral chordae tendineae

机译:确定正常和钙化的人二尖瓣腱索的机械性能

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of the present research is to determine the influence of the calcification of human mitral valves on the mechanical properties of their marginal chordae tendineae. The study was performed on marginal chords obtained from thirteen human mitral valves, explanted at surgery, including six non-calcified, four moderately calcified and three strongly calcified valves. The mechanical response of the chords from the non-calcified and moderately calcified valves was determined by means of quasi-static tensile tests (the poor condition of the strongly calcified valves prevented them from being mechanically characterised). The material parameters that were obtained and analysed (the Young's modulus, the secant modulus, the proportional limit stress, the ultimate strength, the strain at fracture and the density of energy stored up to maximum load) revealed noticeable differences in mechanical behaviour between the two groups of mitral chordae tendineae. Large scatter was obtained in all cases, nevertheless, considering the mean values, it was observed that the normal chords are between three and seven times stiffer or more resistant than the moderately calcified ones. On the contrary, the results obtained for the strain at fracture showed a rather different picture as, in this case, no significant differences were observed between the two families of chords. A scanning electron microscopy study was conducted in order to find out the relevant features of the calcium deposits present in the calcified chordae tendineae. In addition, the general aspects appreciated in the stress vs. strain curves were correlated with the collagen morphological evidences determined microscopically. Finally, the calcium content present in the three groups of chords was quantitatively determined through atomic absorption spectroscopy; then, the relation between the mechanical properties of normal and moderately calcified chords as a function of its calcium content was obtained. This analysis confirmed the existence of a strong correlation between calcium content and stiffness or resistance whereas the influence on the ductility seems to be negligible.
机译:本研究的目的是确定人二尖瓣钙化对其边缘腱索肌腱力学性能的影响。这项研究是在手术切除的13个人类二尖瓣上获得的边缘弦上进行的,其中包括6个非钙化,4个中钙化和3个强钙化的瓣膜。非钙化和中度钙化的瓣膜的弦的机械响应通过准静态拉伸试验确定(强钙化瓣膜的不良状况阻止了它们的机械表征)。所获得和分析的材料参数(杨氏模量,割线模量,比例极限应力,极限强度,断裂应变和最大载荷下存储的能量密度)显示出两者之间的机械性能存在明显差异二尖瓣腱索群。在所有情况下都获得了较大的散布,但是,考虑到平均值,可以观察到,正常的弦比中度钙化的弦坚硬三到七倍,或者具有更高的抵抗力。相反,在断裂处获得的应变结果显示出相当不同的图像,因为在这种情况下,两个和弦家族之间没有观察到显着差异。为了找到钙化腱索中钙沉积的相关特征,进行了扫描电子显微镜研究。另外,在应力-应变曲线中理解的一般方面与在显微镜下确定的胶原形态学证据相关。最后,通过原子吸收光谱法定量测定了三组和弦中的钙含量。然后,获得正常和中度钙化弦的机械性能与其钙含量之间的关系。该分析证实了钙含量与硬度或抗性之间存在很强的相关性,而对延性的影响似乎可以忽略不计。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号