首页> 外文会议>International Conference on Indoor Air Quality and Climate >Indoor radon concentrations in Portuguese schools: preliminary survey results
【24h】

Indoor radon concentrations in Portuguese schools: preliminary survey results

机译:葡萄牙学校的室内氡浓度:初步调查结果

获取原文

摘要

The aim of this preliminary survey is to assess indoor radon concentrations in public schools. Measurements were performed in 13 public primary schools located in Porto by using CR-39 passive radon detectors exposed for approximately 2 months. The anticipation of a considerable variability of radon concentration suggested the need to monitor concentrations in several rooms for different floors. Radon concentrations ranged from 56 to 889 Bq/m~3 (mean = 197 Bq/m~3). The results show that the WHO IAQ guidelines limit of 100 Bq/m~3 is exceeded in 92% of the measurements.
机译:初步调查的目的是评估公立学校的室内氡浓度。通过使用CR-39被动氡探测器约2个月,在Porto的13个公共小学中进行了测量。期待氡浓度相当变化的氡浓度的需求表明需要监测几个房间的浓度,以适用于不同的地板。氡浓度范围为56至889 bq / m〜3(平均值= 197 bq / m〜3)。结果表明,92%的测量中超过了100bq / m〜3的WHO IAQ指南限额。