There have always been improvement activities on fan design of an air-conditioner for more efficient air-flow rate, higher air static pressure and lower sound levels. In doing so, much attention has been put in the design of the fan itself while other surrounding structures, such as fan nozzle & side panels are seldom considered as important factors. This paper investigates how airflow performance of an outdoor unit of air-conditioners can be improved by changing the fan nozzle radius, depth & other surrounding structures while maintaining the fan itself. In the course of the investigations, theories of fluid mechanics are being applied, and experiments are carried out to validate the hypothesis. The experiments were carried out by Design of Experiments so that the significant factors are identified through screening experiments and studied further to understand its effect towards airflow performance. It is concluded that the inlet radius of fan nozzle and the fan guard grille are most significant & airflow improvements are achieved by minimizing flow recirculation & separation.
机译:对于更有效的空气流速,空调的空调,较高的空气静态压力和较低的声级,始终存在改进活动。在这样做时,很多关注都是在风扇本身的设计中,而其他周围结构,如风扇喷嘴和侧面板很少被认为是重要因素。本文通过改变风扇喷嘴半径,深度和其他周围结构,同时保持风扇本身,调查空调室的气流性能如何改善。在调查过程中,正在应用流体力学的理论,进行实验以验证假设。通过实验设计进行实验,使得通过筛选实验来识别重要因素,并进一步研究其对气流性能的影响。得出结论,风扇喷嘴的入口半径和风扇护罩格栅是最显着的,通过最小化流动再循环和分离来实现气流改进。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号