Although cathodically protected pipelines are often connected directly to electrical ground in stations and plants, there is little information on the amount of current required to polarize various grounding materials such as copper, tinned copper, stainless steel, silicon iron, and galvanized steel. This paper presents results of short and long-term cathodic polarization tests on commercially available grounding materials buried in a low resistivity clay and a high resistivity sand. The results indicate that in the non-aerated clay all the grounding materials, that would normally be cathodic to steel, required the same or less current density than steel. In the more aerated sandy soil, the current requirements for all the cathodic materials as well as steel increased by at least 2 orders of magnitude with copper requiting an increase of 3 orders of magnitude. Packaged zinc and magnesium anodes were also included in the testing program since they are occasionally used as grounding electrodes for cathodically protected pipelines.
机译:尽管阴极保护的管道通常直接连接到站和植物中的电路,但是有关偏热铜,镀锡,不锈钢,硅铁和镀锌钢等各种接地材料所需的电流量的信息很少。本文介绍了在低电阻率粘土和高电阻率砂中埋入的市售接地材料的短期和长期阴极偏振测试的结果。结果表明,在非充气粘土中,通常是钢的所有接地材料,所以需要的电流密度相同或更少。在更加充气的砂土中,所有阴极材料的当前要求以及钢的要求增加了至少2个数量级,铜质要求增加3个数量级。包装的锌和镁阳极也包括在测试程序中,因为它们偶尔用作阴极保护管道的接地电极。