首页> 外文会议>Joint International Conference on Infrared and Millimeter Waves >Reflections in gyrotrons with radial output: consequences for the ITER coaxial gyrotron
【24h】

Reflections in gyrotrons with radial output: consequences for the ITER coaxial gyrotron

机译:带径向输出的陀螺仪中的思考:艾滋病同轴陀螺仪的后果

获取原文

摘要

A theory describing the influence of reflections on operation of gyrotrons with radial output is presented. The theory is used for evaluating the effect of reflections on the operation of the 170 GHz ITER coaxial cavity gyrotron. It is shown that for optimally chosen external magnetic field value and electron beam radius, possible reflections do not change the final steady-state operation, which corresponds to generation of a 2.2 MW power.
机译:提出了一种理论,描述了对径向输出的影响反射对陀螺输出的影响。该理论用于评估反射对170GHz迭代同轴腔陀螺仪的操作的影响。结果表明,对于最佳选择的外部磁场值和电子束半径,可能的反射不会改变最终的稳态操作,这对应于2.2 MW功率的产生。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号