Combined Sewer Overflows (CSOs) have been for long time present in the technical literature. A short review of recent contributions is given in the paper. Regulations for reducing CSO impact in the U.S., EU and in Italy are then considered. Different means of controlling CSOs are discussed and among them retention storage is considered as the most frequent. Observations from an experimental catchment in Cosenza, Italy, drained by a combined sewer system with overflow facility, are then presented. They include 28 CSO events, for which the complete hydrographs were registered, obtaining the overflows hydrographs. Six more events were observed for quality data, and TSS, BOD and COD were measured; a regression equation between TSS, BOD and COD was found. Pollutant rates were represented against stormwater volumes, and first foul flush seems to be present only in one of the six events. As EU regulations demand complete storage and treatment of combined sewer overflows, different retention volumes of an off-line tank were analysed, provided that a discharge from 3 to 4 times the dry weather discharge is continuously treated by the treatment plant during storms. Values of the order of 150-200 m~3/ha should reduce the final spill into receiving waters to a few events per year.
机译:合并的下水道溢出(CSO)已经在技术文献中存在了很长时间。纸质中给出了最近贡献的简短回顾。然后考虑在美国,欧盟和意大利减少CSO的规定。讨论了控制CSO的不同手段,其中包括保留存储被认为是最常见的。然后呈现出意大利Cosenza的实验集水区的观察,然后呈现由具有溢出设施的组合下水道系统排出的。它们包括28名CSO事件,其中已登记完全的水文,从而获得溢出的水文。为质量数据观察到六种事件,测量TSS,BOD和COD;发现了TSS,BOD和COD之间的回归方程。污染物率是针对雨水卷的代表性,第一个犯规似乎仅在六场比赛之一中存在。随着欧盟法规要求组合下水道溢出的完全储存和治疗,分析了不同的储存量的离线罐,条件是在暴风雨期间的治疗厂连续治疗干天气排放3〜4倍的排出。 150-200米〜3 /公顷的价值应将最终泄漏减少到接收水域,每年少数活动。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号