TOSCA-Imaging - Developing Internet Based Image Processing Software for Screening and Diagnosis of Diabetic Retinopathy

机译:TOSCA-Imaging - 开发基于互联网的图像处理软件,用于筛选和诊断糖尿病视网膜病变

获取原文

摘要

The primary aim of TOSCA-Imaging, which was a part of the TOSCA Project financed by EU's Fifth Framework 1ST Programme, was to develop Internet based software and image data bases for screening and diagnosis of diabetic retinopathy and implementing it into a real life situation. The work consisted of: 1) Construction of an Internet based communication platform for transmitting and analyzing retinal images. 2) Implementation of routines for detecting the first mi-croaneurysm (transition from normal to pathologic), detecting patients needing referral for treatment (presence of venous beading or hard exudates near thefovea), and for serial analysis (image alignment). 3) Construction of a reference image data base. A preliminary validation showed that decisions that depended on a precise detection of individual lesions, e.g. the detection of normality, had a sensitivity and specificity of around 80%, whereas decisions that depended on the detection of lesion patterns, e.g. clinically significant macular oedema, had a sensitivity and specificity of more than 95%. Validation of the reference image data base by double grading by two expert graders suggested a sensitivity and a specificity of just below 90% for any lesion and of more than 95% for predicting the overall retinopathy grade. TOSCA-Imaging has succeeded in its primary aim of developing Internet based software and implementing it into a real life situation, integrating work within image processing done in four different European countries (England, Germany, Ireland, and Denmark) to be accessed from one Internet web site.
机译:TOSCA成像的主要目标是欧盟第五架构第一计划资助的TOSCA项目的一部分,是为了开发基于互联网的软件和图像数据基础,用于筛选和诊断糖尿病视网膜病变,并将其实施到现实生活中。该工作包括:1)基于互联网的通信平台来发射和分析视网膜图像的构造。 2)实施常规用于检测第一个MI-Croaneurysm的常规(从正常到病理学的转变),检测需要转介治疗的患者(静脉珠粒的存在或硬渗透物附近的硬渗漏物),以及串行分析(图像对准)。 3)参考图像数据库的构造。初步验证表明,依赖于单个病变的精确检测的决定,例如,依赖于单个病变的精确检测。常态的检测具有约80%的敏感性和特异性,而取决于依赖病变模式的决定,例如依赖于病变模式的决定。临床上显着的黄斑水肿,具有95%以上的敏感性和特异性。通过两位专家分级机通过双分级验证参考图像数据基础提出了任何病变的敏感性,特异性低于90%,并且超过95%以预测总体视网膜病变等级。 Tosca-Imaging在基于互联网的软件和实施现实情况的主要目标中取得了成功,将工作整合在四个不同的欧洲国家(英国,德国,爱尔兰和丹麦)中完成的图像处理,从一互联网上访问网站。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号