Existing test methods for thick-section specimens ( ≥ 4[mm]) have not provided precise compressive properties to date for the analysis and design of thick structure. In the current study, the cause of the premature failure for thick specimens (T800/924C and IM7/8552) was identified experimentally and numerically. The premature failure was successfully avoided during compressive testing and the failure mode was quite similar regardless of increasing specimen thickness and specimen volume. Furthermore it was identified that the failure location within gauge section does not have an influence on the compressive strength from the experimental result performed with the unwaisted specimens and the waisted specimens. Finally, clear 1-D thickness and 3-D scaling effects on the compressive strength of unidirectional composite laminates existed. The main factors influencing the effects were due to manufacturing defects such as void content and fibre waviness.
机译:厚截面样品的现有测试方法(≥4[mm])迄今未提供精确的压缩性能,以进行厚结构的分析和设计。在目前的研究中,实验和数值鉴定了厚试样过早失效的原因(T800 / 924C和IM7 / 8552)。在压缩测试期间成功避免了过早的故障,无论样品厚度和样品体积增加,故障模式都非常相似。此外,鉴定了规格部分内的故障位置不会对从不承旧的样本和腰部样本进行的实验结果产生压缩强度的影响。最后,存在清晰的1-D厚度和3-D对单向复合层压材料的抗压强度的缩放效果。影响效果的主要因素是由于制造缺陷,例如空隙含量和纤维波纹。