首页> 外文会议>IEEE Industry Applications Conference >An Advanced Technique for Detecting Inter-laminar Stator Core Faults in Large Electric Machines
【24h】

An Advanced Technique for Detecting Inter-laminar Stator Core Faults in Large Electric Machines

机译:一种用于检测大型电机层间定子芯断层的先进技术

获取原文

摘要

An advanced technique for detecting incipient inter-laminar insulation failure in stator cores of large electric machines is proposed in this paper. The proposed scheme is an off-line method based on low flux stator core excitation that employs a new probe. An iron-core probe is placed in the wedge depression area of the stator and scanned axially to detect the variation in the measured flux due to a fault. Two fault indicators that provide clear indication on fault severity and location are proposed in this paper. A 120MW AC machine stator was tested under a number of intentionally inserted fault conditions using a portable field equipment recently developed. The experimental results show that the fault existence, location, and severity can be determined reliably using the proposed scheme. It is also shown that the fault detection sensitivity and reliability, inspection speed, and user convenience are significantly enhanced.
机译:本文提出了一种用于检测初级电机中的初级层内绝缘失效的先进技术。所提出的方案是基于使用新探针的低通量定子芯激发的离线方法。将铁芯探针置于定子的楔形凹陷区域中,并轴向扫描,以检测由于故障引起的测量磁通量的变化。本文提出了两个故障严重性和位置的清晰指示的故障指示。使用最近开发的便携式现场设备在许多有意插入的故障条件下测试120mW AC机定子。实验结果表明,可以使用所提出的方案可靠地确定故障存在,位置和严重程度。还示出了故障检测灵敏度和可靠性,检查速度和用户便利性得到了显着提高。