SIMULATION OF HEAT EXCHANGERS OF A WINDOW AIR CONDITIONER RETROFITTED WITH R-407C

机译:用R-407C进行窗户空调的热交换器仿真

获取原文

摘要

This paper presents the results of simulation of heat exchangers of an HCFC-22 window air conditioner retrofitted with R-407C. The test conditions considered are as per the Indian Standard IS 1391 (1992) for unitary air conditioners. The simulation has been carried out using EVAP-COND, a heat exchanger model developed by NIST. A typical Indian window air conditioner of capacity 5.13 kW (1.5 TR) has been selected for the study. The performance of heat exchangers with R-407C is compared with the baseline performance with HCFC-22. The simulated results are validated by comparing with experimental results of window air conditioner retrofitted with R-407C. The assessment parameters considered are temperatures of refrigerant and air, and pressures with pressure drop in the refrigerant flow. The simulated evaporator capacity with R-407C is lower by 3.3% for the lower outdoor conditions and 6% lower for the higher outdoor conditions with respect to HCFC-22. R-407C has 6.1% lower condenser capacity for the lower outdoor conditions and 10.6% lower for the higher outdoor conditions with respect to HCFC-22. The simulated evaporator capacities are within ±3% of the experimentally measured cooling capacities for both the refrigerants. The exit temperatures of R-407C are lower in the range 1.9°C to 5.2°C in the condenser and are higher in the range 3.2°C to 3.8°C in the evaporator compared to HCFC-22. The evaporating pressures of R-407C are higher in the range 4.5% to 5.3% than HCFC-22. The condensing pressures of R-407C are higher in the range 10.3% to 14.1% than HCFC-22. The pressure drop of R-407C is lower in both evaporator and condenser than HCFC-22. The outlet temperatures of air for HCFC-22 and R-407C in both the heat exchangers are almost similar.
机译:本文介绍了HCFC-22窗口空调的热交换器仿真结果,R-407C改装。考虑的测试条件根据印度标准为单一空调的1391(1992)。使用NIST开发的eVAP-COND进行了模拟。该研究已选择典型的印度窗户空调5.13千瓦(1.5 TR)。将具有R-407C的热交换器的性能与HCFC-22的基线性能进行比较。通过与R-407C改装窗口空调的实验结果进行比较,验证模拟结果。所考虑的评估参数是制冷剂和空气的温度,以及制冷剂流动压降的压力。对于较低的室外条件,利用R-407C的模拟蒸发器容量较低3.3%,对于HCFC-22的较高的室外条件,较高的室外条件下降6%。 R-407C的较低室外条件的冷凝器容量降低了6.1%,对于HCFC-22的较高的室外条件,降低了10.6%。模拟蒸发器容量在实验测量的冷却能力的±3%以内,用于制冷剂。 R-407C的出口温度在冷凝器中的1.9℃至5.2℃的范围内较低,与HCFC-22相比,蒸发器中的3.2℃至3.8°C的范围内。 R-407C的蒸发压力较高的范围为4.5%至5.3%而不是HCFC-22。 R-407C的冷凝压力越高,距离比HCFC-22的10.3%至14.1%。蒸发器和冷凝器的R-407C的压降比HCFC-22较低。热交换器中HCFC-22和R-407C的空气的出口温度几乎相似。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号