In the rigid-rigid THR, the incidence of impingement, subluxation and dislocation have been of some interest. In this case of all-ceramic THR, we followed a patient who presented with a loud clicking noise as she ambulated. At retrieval operation, the posterior femoral neck had two notches. The protruding rim of the metal cup was excised with a high-speed burr. SEM analysis showed that main wear zone (MWZ) had high wear, and peripheral wear zone (PWZ) had severe wear. Therefore these data indicade that poor positioning of a rigid socket may not only create the problems of impingement but may also accelerate the wear of the ceramic ball.
机译:在刚性刚性Thr中,冲击的发生率,子统计和错位具有一些兴趣。在这种情况下,在全陶瓷thr,我们遵循一个患者,患者在偷窥时呈现出响亮的噪音。在检索操作时,后股股骨颈部有两个凹口。用高速毛刺切除金属杯的突出边缘。 SEM分析表明,主磨损区(MWZ)具有高磨损,外围磨损区(PWZ)具有严重的磨损。因此,这些数据表明,刚性插座的较差的定位可能不仅可以产生冲击的问题,而且还可以加速陶瓷球的磨损。