首页> 外文会议>Meeting of the International Group on Research Reactors >Transient analysis of the new Cold Source at the FRM-II
【24h】

Transient analysis of the new Cold Source at the FRM-II

机译:FRM-II新冷源的瞬态分析

获取原文

摘要

The new Cold Source (CNS) at the FRM-II research reactor is completely installed. This paper reports on the results of the transient analysis in the design status for this facility for producing cold neutrons for neutron experiments, the implementation of the results in the design of the mechanical components, the measurements at the cold tests and the comparison with the data of the transient analysis. The important load cases are fixed in the system description and the design data sheet of the CNS. A transient analysis was done with the computer program ESATAN, the nodal configuration was identical with the planned system of the CNS and the boundary conditions were chosen so, that conservative results can be expected. The following transients of the load cases in the piping system behind the inpile part normal storage of D_2 at the hydride storage vessel breakdown of cooling system of the CNS and transfer of D_2 to the buffer tank rapid charge of D_2 to the buffer tank with break of the insulation vacuum and flooding of Neon reloading of the D2 from the buffer tank to the D_2 hydride storage vessel were calculated. Additionally the temperature distribution for these transients in the connecting flanges of the systems to the inpile part were analysed. The temperature distributions in the flange region were take into account for the strength calculation of the flange construction. The chosen construction shows allowable values and a leak tight flange connection for the load cases. The piping system was designed to the lowest expected temperatures. The load cases in the moderator tank were take into account in the stress analysis and the fatigue analysis of the vacuum vessel and the moderator vessel. The results shows allowable stresses. The results shows that a transient analysis is necessary and helpful for good design of the CNS.
机译:完全安装了FRM-II研究反应堆的新冷源(CNS)。本文报告了该设施为中子实验生产冷中子设计状态的瞬态分析结果,实现了机械部件设计的结果,在冷测试的测量和与数据的比较瞬态分析。重要的负载情况在系统描述和CNS的设计数据表中固定。使用计算机程序Esatan进行瞬态分析,节点配置与CNS的计划系统相同,并且选择了边界条件,因此可以预期保守结果。以下瞬态在管道系统中的循环系统,在氢化物储存容器中的氢化物储存容器中的氢化物储存容器的崩溃和D_2的转移到缓冲罐的快速充电D_2到缓冲罐中断计算了从缓冲罐到D_2氢化物储存容器中D2的绝缘真空和挤出D2。另外,分析了这些瞬变在系统的连接法兰中的这些瞬变的温度分布被分析到INPILE部分。考虑到法兰结构的温度分布,以实现法兰结构的强度计算。所选择的施工显示允许值和用于负载情况的泄漏紧密法兰连接。管道系统设计为最低预期温度。考虑到压力分析以及真空容器的疲劳分析和主持人容器中的负载箱中的负载箱。结果显示允许的应力。结果表明,瞬态分析是必要的,并有助于良好的CNS设计。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号