Influence of pile installation and of pile test procedure on the test load results of Atlas pile ― A case study

机译:桩安装和桩试验的影响对地图集桩的试验载荷结果 - 以案例研究

获取原文

摘要

Installation details for test and reaction piles have an influence on the initial soil stress condition around the test pile. Shaft capacity and skin friction in some cases is the major contributor to the total pile capacity and can directly be influenced by pile installation and pile test procedure. Inter-distance between test pile and reaction piles are usually taken in consideration in order to avoid mutual interaction. As a key element of a high speed rail project, 7km long, 10m wide, 450mm deep reinforced concrete piled slab foundation over the Thames Marshes needed to be investigated. For this purpose, three instrumented Atlas piles with different lengths were tested vertically both statically and cyclically. Four CFA anchor piles were acting as reaction piles for each test pile, two of which where shared between every sequent test piles. The results showed the interaction of the anchor piles with the test pile and showed also some test sequence influence. Strain gauges readings showed an uplifting force on the test pile induced by the utilized anchor piles even when there was zero load applied on the pile head.
机译:测试和反应桩的安装细节对测试桩周围的初始土壤应力条件产生影响。在某些情况下,轴容量和皮肤摩擦是总桩容量的主要原因,可以直接受桩安装和桩测试程序的影响。测试桩和反应桩之间的间间通常考虑以避免相互互动。作为高速铁路工程的关键要素,7km长,10米宽,450mm深钢筋混凝土堆积在泰晤士沼泽上需要进行调查。为此目的,静态和循环地垂直测试具有不同长度的三个具有不同长度的仪表标的地图集桩。四个CFA锚桩作为每个测试桩的反应桩,其中两个在每个搜索桩之间共享的两个测试桩。结果表明,锚桩与试验桩的相互作用,并显示出一些测试序列影响。应变仪读数显示出在桩头上施加零负荷时由使用的锚固桩引起的测试桩上的升高力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号