首页> 外文会议>International conference on grouting and ground treatment >Column penetration tests for lime-cement columns in deep mixing -experiences in Sweden
【24h】

Column penetration tests for lime-cement columns in deep mixing -experiences in Sweden

机译:瑞典深混合中的石灰水泥柱柱渗透试验

获取原文

摘要

In this paper column penetration tests for lime-cement columns in deep mixing are reviewed. In principle, column penetration tests and reversed column penetration tests are considered. Improved test techniques are presented and discussed based on tests from two test sites in Sweden. The investigations indicate that the reversed column penetration test is the most suitable method for the primary quality test with reference to the uniformity and continuity of the columns. The probe should, however, be installed by the lime-cement column machine short after the manufacturing of the column to avoid disturbances in the mixing process and to enable a random test selection.
机译:在本文的纸张中,回顾了深混合中的石灰水泥柱的渗透试验。原则上,考虑柱穿透试验和反转柱渗透测试。提出并讨论了改进的试验技术,并根据瑞典的两个测试站点的测试讨论。调查表明,反向柱渗透试验是参考列的均匀性和连续性的主要质量测试最合适的方法。然而,探头应由石灰水泥柱机安装在制造柱后短路,以避免混合过程中的干扰,并能够实现随机测试选择。