A weakly absorbing species, molecular oxygen’s analytical sensitivity is dramatically enhanced by catalytic transformation to moisture vapor followed by Cavity Ring-Down Spectroscopy (CRDS) analysis of the product in a fast and quantitative manner. This concept has resulted in a high-performance trace oxygen gas analyzer with no wet chemistry involved and no zero or span calibration required. The instrument has an estimated lower detection limit of ~100 parts-pertrillion (ppt), as well as excellent linearity and accuracy based on extensive in-house evaluation, as well as customer site Beta testing against NIST traceable blend standards.
机译:通过催化转化对水分蒸气显着提高了弱吸收的物种,分子氧的分析敏感性随着腔循环光谱(CRD)以快速和定量的方式分析产物。该概念导致高性能痕量氧气分析仪,没有涉及湿化学,无需零或跨度校准。该仪器估计较低的检测限〜100份 - Pertlillion(PPT),以及基于广泛的内部评估,以及针对NIST可追踪混合标准的客户现场测试版,优异的线性度和准确性。